Flash - KZIII

By Zorlu (TVS)


Functional unit
Parameter
Value
Functional unit
kWh
Parameter
Applicability
range
Bagnore data
Your value
Unit
Description
fNCG
0.005 - 0.12
0.07
ratio
Mass fraction of NCGs in the geofluid
Power output
20000 - 120000
60000
kW
Electrical Machinery Capacity
Flow rate
110000 - 1000000
400000
kg/hour
Flow rate of the geofluid at the power plant inlet
fH2S
0.0013 - 0.054
0.017868
ratio
Relative fraction of H2S in the geofluid
fHg
9.00E-06 - 3.00E-5
0.000018
ratio
Relative fraction of Hg in the geofluid
Make-up wells ratio
0 - 0.76
0
ratio
Ratio of make-up wells drilled yearly
Average length of wells
586 - 4727
2273
meters
Average length of wells
Table 4
Standard Deviation* of simplified models
Impact category
* Standard deviation
Climate change
Freshwater and terrestrial acidification
Freshwater ecotoxicity
Human health - carcinogenic effects
Human health - non-carcinogenic effects
Resources - fossils
Resources - minerals and metals
*the standard deviation provided does not reflect the uncertainty of the estimated value, but the spread in the results when doing a Monte Carlo simulation over the validity ranges of the simplified models' parameters.
Table 5
Your results
Impact category
Value
Unit
Functional unit
Climate change
kg CO2-Eq
kWh electric
Freshwater and terrestrial acidification
mol H+-Eq
kWh electric
Freshwater ecotoxicity
CTUe
kWh electric
Human health - carcinogenic effects
CTUh
kWh electric
Human health - non-carcinogenic effects
CTUh
kWh electric
Resources - fossils
MJ
kWh electric
Resources - minerals and metals
kg Sb-Eq
kWh electric
Median results of the reference LCA model relative to your results
Simplified models results using the case-study data, relative to your results
Reference model comparison
Simplified model comparison (Generalized)