EGS Model

LCA Tool


Instructions on the use of Simplifed LCA models
Info

Fill in your values of the parameters in the yellow fields in Table 1, according to the applicability range of the simplified model, and
impact categories of interest. Information on input values needed per impact category can be found in Table 2. Table 3 shows the
standard deviation of simplified models.

Functional unit
Parameter
Value
Functional unit
kWh
Table 1
Parameter
Applicability
range
Generalized data
Your value
Unit
Description
fNuc
0 - 1
0.76
ratio
Ratio of nuclear power in the national grid
fCoal
0 - 1
0.041
ratio
Ratio of coal in the national grid
fOil
0 - 1
0.01
ratio
Ratio of oil in the national grid
fNG
0 - 1
0.05
ratio
Ratio of natural gas in the national grid
fBio
0 - 1
0.01
ratio
Ratio of biomass in the national grid
fHydro
0 - 1
0.11
ratio
Ratio of hydropower in the national grid
fWind
0 - 1
0.018
ratio
Ratio of wind in the national grid
fSolar
0 - 1
0.00
ratio
Ratio of solar in the national grid
Thermal output
10 - 40
22.5
MW
Thermal power output
Power of the production pump
200 - 1200
500
kW
Power of the production pump
Power of the injection pump
0 - 500
0
kW
Power of the injection pump
Number of production wells
1 - 2
1
Number of
Number of production wells
Number of injection wells
1 - 2
1
Number of
Number of injection wells
Well lengths
1300 - 5500
2888
meters
Average well length
All fields are mandatory
Table 2
Inputs need per impact category
Climate change
Thermal output; Power of the production pump; Power of the injection pump; Number of production and injection wells; Average well length as well as shares of electricity;
Freshwater and terrestrial acidification
Thermal output; Power of the production pump; Power of the injection pump; Number of production and injection wells; Average well length as well as shares of electricity;
Freshwater ecotoxicity
Thermal output; Power of the production pump; Power of the injection pump; Number of production and injection wells; Average well length as well as shares of electricity;
Human health - carcinogenic effects
Thermal output; Power of the production pump; Power of the injection pump; Number of production and injection wells; Average well length as well as shares of electricity;
Human health - non-carcinogenic effects
Thermal output; Power of the production pump; Power of the injection pump; Number of production and injection wells; Average well length as well as shares of electricity;
Resources - fossils
Thermal output; Power of the production pump; Power of the injection pump; Number of production and injection wells; Average well length as well as shares of electricity;
Resources - minerals and metals
Thermal output; Power of the production pump; Power of the injection pump; Number of production and injection wells; Average well length as well as shares of electricity;
Table 4
Standard Deviation* of simplified models
Impact category
* Standard deviation
Climate change
Freshwater and terrestrial acidification
Freshwater ecotoxicity
Human health - carcinogenic effects
Human health - non-carcinogenic effects
Resources - fossils
Resources - minerals and metals
*the standard deviation provided does not reflect the uncertainty of the estimated value, but the spread in the results when doing a Monte Carlo simulation over the validity ranges of the simplified models' parameters.
Table 5
Your results
Impact category
Value
Unit
Functional unit
Climate change
kg CO2-Eq
kWh heat
Freshwater and terrestrial acidification
mol H+-Eq
kWh heat
Freshwater ecotoxicity
CTUe
kWh heat
Human health - carcinogenic effects
CTUh
kWh heat
Human health - non-carcinogenic effects
CTUh
kWh heat
Resources - fossils
MJ
kWh heat
Resources - minerals and metals
kg Sb-Eq
kWh heat
Median results of the reference LCA model relative to your results
Simplified models results using the case-study data, relative to your results
Reference model comparison
Simplified model comparison (Generalized)

General information on the SM

Instructions on the use of Simplifed LCA models

Terminology

ElectricalShares

LIFE CYCLE ASSESSMENT (LCA) MODELS

EGS

Enhanced Geothermal System technology for heat generation with very low direct emissions.

Calculate Model

FLASH

Type of geothermal power plants that produce electricity thanks to the steam that drives generator turbines. These plants also produce heat which is delivered through a heat transfer network for industrial uses.

Calculate Model

CHP

Combined Heat and Power geothermal plants with low direct emissions.

Calculate Model

HeatORC

A heat production plant including a demonstration Organic Rankine Cycle (ORC) producing electricity for self-consumption with very low emissions.

Calculate Model